SY Static mixer
Product details

The inner unit of a SY type static mixer consists of cross bars, which are 45 degrees along the axis of the tube. The mixed effect of SY type is between SV type and SK type, which can disperse the droplets to 2-5um during the differentiation process, and it can be used for a mixing process. The non-uniformity coefficient of a X X - 2 is less than 1% amplification effect.


The pressure drop calculation formula

P=(f*ρc/ε2W2)*L/dh                 Re=dh*ρc*w/μ*ε   
W=(Q/πD2*900)*10^6               1Kgf/cm2=98100N/m2
dh=(πD2L-4Aδ)/(2A+πDL)
PPressure drop(N/m2)          f Friction coefficient (dimensionless)     ρcFluid density(Kg/m3)
WFluid linear velocity(m/s      LMixer length(mm      dhThe hydraulic diameter(mm
εVoid fraction (dimensionless)           μFluid viscosity(CP           AThe total area of the mixed unit(mm2)
δUnit material thickness(mm    DPipe diameter(mm        ReReynolds number (dimensionless)


The relationship between Reynolds number Reε and friction coefficient f

 

SY

Laminar flow

range

Re D < 23

Relation between

ΨD =430/Re D

Transition flow zone

range

23 < Re D < 300

Relation between

ΨD =87.2 Re D -0.491

Turbulence zone

range

300 < Re D < 1100

Relation between

ΨD =17.0 Re D -0.205

Completely turbulent region

range

Re D < 1100

Relation between

ΨD =2.53










SY Technical parameter list

Gauge

Nominal diameter

mm

The hydraulic diameter

mm

Flow rate

m3/h

Gauge

Nominal diameter

mm

The hydraulic diameter

mm

Flow rate

m3/h

SY-12.5/25

25

12.5

0.7-1.4

SY-100/200

200

100

56-110

SY-16./32

32

16

1.4-2.9

SY-125/250

250

125

88-176

SY-20/40

40

20

2.3-4.6

SY-150-300

300

150

127-255

SY-25/50

50

25

3.5-7

SY-175/350

350

175

173-346

SY-40/80

80

40

9-18

SY-200/400

400

200

226-452

SY-50/100

100

50

14-28

SY-250/500

500

250

353-706

SY-75/150

150

75

32-64

SY-300/600

600

300

410-814


Description:

1. Nominal pressure is selected according to the user's process conditions
2. Materials: stainless steel, carbon steel, titanium, polyfluorine, polypropylene, etc

3. Flange standard: matching with the user interface, the matching flange can be provided

4. The hybrid unit can be designed and manufactured as a drawable or stationary

5. Flow rate per hour is based on water