The inner unit of a SY type static mixer consists of cross bars, which are 45 degrees along the axis of the tube. The mixed effect of SY type is between SV type and SK type, which can disperse the droplets to 2-5um during the differentiation process, and it can be used for a mixing process. The non-uniformity coefficient of a X X - 2 is less than 1% amplification effect.
The
pressure drop calculation formula
△P=(f*ρc/ε2W2)*L/dh
Re=dh*ρc*w/μ*ε
W=(Q/πD2*900)*10^6
1Kg(f)/cm2=98100N/m2
dh=(πD2L-4Aδ)/(2A+πDL)
△PPressure drop(N/m2)
f Friction
coefficient (dimensionless)
ρcFluid density(Kg/m3)
WFluid linear
velocity(m/s)
LMixer length(mm)
dhThe hydraulic diameter(mm)
εVoid fraction (dimensionless) μFluid viscosity(CP)
AThe total area of the mixed unit(mm2)
δUnit material thickness(mm)
DPipe diameter(mm)
ReReynolds number (dimensionless)
The
relationship between Reynolds number Reε and friction
coefficient f
|
SY
|
Laminar flow
|
range
|
Re D < 23
|
Relation between
|
ΨD =430/Re D
|
Transition flow zone
|
range
|
23 < Re D < 300
|
Relation between
|
ΨD =87.2 Re D -0.491
|
|
|
|
Turbulence zone
|
range
|
300 < Re D < 1100
|
Relation between
|
ΨD =17.0 Re D -0.205
|
Completely turbulent region
|
range
|
Re D < 1100
|
Relation between
|
ΨD =2.53
|
SY Technical parameter list
Gauge
|
Nominal diameter
mm
|
The hydraulic diameter
mm
|
Flow rate
m3/h
|
Gauge
|
Nominal diameter
mm
|
The hydraulic diameter
mm
|
Flow rate
m3/h
|
SY-12.5/25
|
25
|
12.5
|
0.7-1.4
|
SY-100/200
|
200
|
100
|
56-110
|
SY-16./32
|
32
|
16
|
1.4-2.9
|
SY-125/250
|
250
|
125
|
88-176
|
SY-20/40
|
40
|
20
|
2.3-4.6
|
SY-150-300
|
300
|
150
|
127-255
|
SY-25/50
|
50
|
25
|
3.5-7
|
SY-175/350
|
350
|
175
|
173-346
|
SY-40/80
|
80
|
40
|
9-18
|
SY-200/400
|
400
|
200
|
226-452
|
SY-50/100
|
100
|
50
|
14-28
|
SY-250/500
|
500
|
250
|
353-706
|
SY-75/150
|
150
|
75
|
32-64
|
SY-300/600
|
600
|
300
|
410-814
|
Description:
1. Nominal pressure is selected according to the user's process conditions
2. Materials: stainless steel, carbon steel, titanium, polyfluorine, polypropylene, etc
3. Flange standard: matching with the user interface, the matching flange can be provided
4. The hybrid unit can be designed and manufactured as a drawable or stationary
5. Flow rate per hour is based on water
|